Konstruktion des Regelventils

Konstruktion des Regelventils

Konstruktion des Regelventils

Saddle regulating valve (linear) - made based on a saddle valve. Regulation is carried out by changing the flow area between the shutter and the seat. Linear regulating valves of this type are so named because they are used together with electric drives with linear movement of the stem.

The universal design of the valve allows to create virtually any flow characteristic by modifying the shutter and seat. Excellent regulating characteristics and simple construction of the regulating valve with a saddle shutter have contributed to its wide use in building engineering systems.

The only drawback of linear valves is the complex shape of the flow part, which is unsuitable for viscous media.

Ball regulating valve (rotary)

Ball regulating valve (rotary) - made based on a ball valve. Regulation is carried out by changing the flow area by rotating the ball around an axis perpendicular to the direction of water flow.

The flow area of the ball can be circular or have another shape. Rotary regulating valves of this type are so named because they are used together with drives with radial rotation of the stem.

Ball regulating valves are used together with rotary drives with high closing force and are controlled by radial movement of the stem. The drawbacks of ball regulating valves are the need for expensive electric drives with high closing force and the difficulty of creating a linear or equal percentage flow characteristic - as a result, low regulation accuracy.

The advantages include a simple flow part shape suitable for use with viscous working media.

Regulating valves are classified by the presence of a protective function:

  • Normally open - open the flow area when power is turned off.
  • Normally closed - close the flow when power is turned off.
  • Without protective function - the valve stops when power is turned off.

Frage : Kommentar : Rückmeldung

wo über die Antwort benachrichtigen. wird nirgendwo veröffentlicht

49

Kvs
Durchflusskoeffizient
m³/h
PN
Nennbetriebsdruck PN
bar
Ihr Produkt dem Katalog hinzufügen

Gemeinschaft von Experten

Wir sammeln eine Gemeinschaft von Experten für die Planung, Installation und Wartung von Heizungs-, Warmwasser- und Wasserversorgungssystemen in Land of dreams. Treten Sie der Gemeinschaft bei und Sie erhalten E-Mails mit Arbeitsanfragen in Land of dreams von unseren Besuchern.

Planung
Installation
Wartung
Heizung
Wasserversorgung
Klimaanlage
Werbung auf der Website
3 190 visitors yesterday
visitors per month
6 from Land of dreams
49 243 from all countries