model |
V liter |
h mm |
d mm |
m kg |
PN bar |
PNт bar |
F mm |
q kW |
St m² |
Ss m² |
price |
---|---|---|---|---|---|---|---|---|---|---|---|
Vitocell 100-V CVA 160 | 160 | 1189 | 581 | 86 | 10 | 25 | ? | 0.060 | 1.0 | - | production of discontinued |
Vitocell 100-V CVA 200 | 200 | 1409 | 581 | 97 | 10 | 25 | ? | 0.070 | 1.0 | - | production of discontinued |
Vitocell 100-V CVA 300 | 300 | 1746 | 633 | 151 | 10 | 25 | ? | 0.090 | 1.5 | - | production of discontinued |
Vitocell 100-V CVA 500 | 500 | 1955 | 850 | 181 | 10 | 25 | 100 | 0.13 | 1.9 | - | production of discontinued |
Vitocell 100-V CVA 750 | 750 | 2100 | 960 | 295 | 10 | 25 | 105 | 0.15 | 3.7 | - | production of discontinued |
Vitocell 100-V CVA 1000 | 1000 | 2160 | 1060 | 367 | 10 | 25 | 105 | 0.18 | 4.0 | - | production of discontinued |
V - volume, liters.
h - height, mm.
d - diameter (dimensions) with thermal insulation, mm.
m - mass, kg.
PN - nominal pressure for the tank, bar.
PN т - nominal pressure for the heat exchanger, bar.
F - thickness of tank insulation, mm.
q - thermal losses from the surface of the thermal storage tank, kW at dt=40°C.
St - surface area of the heat exchanger, m².
Ss - surface area of the heat exchanger for the solar collector, m².
question : comment : feedback
2 659 | visitors yesterday |
visitors per month | |
46 | from Land of dreams |
74 238 | from all countries |