model | N kW |
Vf m³ |
Тst mm |
Vw l |
Ps Pa |
ds mm |
DN mm |
m kg |
H:W:D mm |
price |
---|---|---|---|---|---|---|---|---|---|---|
КТТ-С 12 | 12 | 0.022 | 4 | 41 | 25 | 150 | 40 | 100 | 895 470 680 |
production of discontinued |
КТТ-С 16 | 16 | 0.028 | 4 | 47 | 25 | 150 | 40 | 110 | 895 470 760 |
production of discontinued |
КТТ-С 20 | 20 | 0.045 | 4 | 58 | 25 | 150 | 40 | 130 | 1110 470 760 |
production of discontinued |
КТТ-С 30 | 30 | 0.095 | 5 | 70 | 30 | 150 | 50 | 230 | 1207 548 855 |
production of discontinued |
КТТ-С 50 | 50 | 0.124 | 6 | 85 | 40 | 210 | 50 | 435 | 1610 552 1100 |
production of discontinued |
N - thermal capacity of solid fuel boiler, kW. Usually specified by the manufacturer for burning coal of the 'Anthracite' grade.
Vf - maximum volume of one-time fuel loading, m³.
Тst - thickness of the steel (cast iron) wall of the combustion chamber, mm.
Vw - volume of water in the boiler, l.
Ps - minimum vacuum in the boiler chimney, Pa.
ds - diameter of the chimney flange at the boiler outlet, mm.
DN - nominal diameter of connecting flanges, at the inlet and outlet of the solid fuel boiler, mm
m - weight of the boiler, kg.
H:W:D - overall dimensions of the boiler, Height : Width : Depth, mm.
question : comment : feedback
2 466 | visitors yesterday |
visitors per month | |
30 680 | from United States |
73 834 | from all countries |
Made in Ukraine
Subscribe
We do not sell equipment. Our goal is to help calculate and select the appropriate equipment. Companies can register on this website, add their equipment, and specify its price.