model | N kW |
Vf m³ |
Тst mm |
Vw l |
Ps Pa |
ds mm |
DN mm |
m kg |
H:W:D mm |
price |
---|---|---|---|---|---|---|---|---|---|---|
Solida 3 | 16 | 0.017 | - | 23 | 8 | 147 | 50 | 175 | 1082 469 355 |
production of discontinued |
Solida 4 | 21 | 0.026 | - | 27 | 10 | 147 | 50 | 210 | 1082 469 455 |
production of discontinued |
Solida 5 | 26 | 0.034 | - | 31 | 12 | 147 | 50 | 245 | 1082 469 555 |
production of discontinued |
Solida 6 | 30 | 0.043 | - | 35 | 13 | 147 | 50 | 280 | 1082 469 655 |
production of discontinued |
Solida 7 | 35 | 0.051 | - | 39 | 15 | 147 | 50 | 315 | 1082 469 755 |
production of discontinued |
Solida 8 | 40 | 0.060 | - | 43 | 18 | 147 | 50 | 350 | 1082 469 855 |
production of discontinued |
N - thermal capacity of solid fuel boiler, kW. Usually specified by the manufacturer for burning coal of the 'Anthracite' grade.
Vf - maximum volume of one-time fuel loading, m³.
Тst - thickness of the steel (cast iron) wall of the combustion chamber, mm.
Vw - volume of water in the boiler, l.
Ps - minimum vacuum in the boiler chimney, Pa.
ds - diameter of the chimney flange at the boiler outlet, mm.
DN - nominal diameter of connecting flanges, at the inlet and outlet of the solid fuel boiler, mm
m - weight of the boiler, kg.
H:W:D - overall dimensions of the boiler, Height : Width : Depth, mm.
question : comment : feedback
2 466 | visitors yesterday |
visitors per month | |
30 680 | from United States |
73 834 | from all countries |
Made in Ukraine
Subscribe