NC FL Calpeda
Circulation pump

production of discontinued

calculation and selection
77 % - model rating
Design NC FL Calpeda Circulation pump Scheme NC FL Calpeda Circulation pump
Техническое описание
Model
NC FL
Manufacturer
Country
Italy
Allowable working fluids
Water
PN
10 / 6
Tmax (for water)
120 °C
Tmin (for water)
-10 °C
Body material
cast iron
Construction
in-line
Energy efficiency index
?
IP protection class
IP 43
Recommended for systems
HVAC - Heating, Ventilation, and Air Conditioning
Suitable for drinking water
not allowed
Connection type
flanged

technical
specifications
price

model
pump
diagram DNin
DNout
U
V
P
kWt
rpm
price
NCM 40-80-220 40
40
230 0.21 ? production of discontinued
NCM 40-85-220 40
40
230 0.28 ? production of discontinued
NCM 40-60-250 40
40
230 0.29 2690
2360
1820
production of discontinued
NCM 40-120-250 40
40
230 0.55 2750
2100
1270
production of discontinued
NCM4 50-60-280 50
50
230 0.42 1260
1030
740
production of discontinued
NCM 50-120-280 50
50
230 0.83 2720
1870
1450
production of discontinued
NC4 40-40-250 40
40
400 0.24 1440
1200
660
production of discontinued
NC 40-60-250 40
40
400 0.32 2790
2240
1440
production of discontinued
NC 40-120-250 40
40
400 0.56 2820
2200
1250
production of discontinued
NC4 50-40-280 50
50
400 0.34 1450
1220
620
production of discontinued
NC4 50-60-280 50
50
400 0.47 1400
1000
560
production of discontinued
NC 50-120-280 50
50
400 0.95 2800
2330
1270
production of discontinued
NC4 65-30-340 65
65
400 0.40 1430
1150
600
production of discontinued
NC4 65-60-340 65
65
400 0.60 1370
950
450
production of discontinued
NC 65-120-340 65
65
400 1.6 2810
2200
1250
production of discontinued
NC4 80-60-360 80
80
400 0.96 1350
1000
600
production of discontinued
NC 80-120-360 80
80
400 2.2 2800
2160
1200
production of discontinued

U, V - supply voltage, V.

P - electric power of the pump, kW.

rpm - rotation speed of the impeller.

DNin/DNout - nominal diameter of the inlet and outlet nozzles, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
Head
m
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
4 090 visitors yesterday
visitors per month
28 256 from United States
74 238 from all countries
add your company to the catalog