PolluTherm WP-Dynamic Sensus
Heat meter

production of discontinued

calculation and selection
63 % - model rating
Drawing PolluTherm WP-Dynamic Sensus Heat meter Design PolluTherm WP-Dynamic Sensus Heat meter Scheme PolluTherm WP-Dynamic Sensus Heat meter
Паспорт
Сертифікат відповідності
Сертифікат затвердження
Model
PolluTherm WP-Dynamic
Manufacturer
Country
Slovakia
Сalculator
PolluTherm
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
16 months
Daily archive
512 days
Archive by hours
option
Downtime
registers
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
145 °C
Temperature difference Min
3 °C
Temperature sensor
Pt500
Length of the sensor
100 mm
Tmax
150 °C
Tmin
1 °C
Standard cable length
3 m
Maximum cable length
23 m
Flow sensor
WP-Dynamic Sensus
Type
mechanical
Dynamic range
?
Standard cable length
3 m
Maximum cable length
? m
PN
16
Tmax
150 °C
Tmin
5 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
40 10
2

0.60

20

2

220

3DN
1DN
production of discontinued
50 15
2

0.60

30

3

200

3DN
1DN
production of discontinued
65 25
2

1

60

4

200

3DN
1DN
production of discontinued
80 45
3

1

90

3

225

3DN
1DN
production of discontinued
100 70
8

2

140

5

250

3DN
1DN
production of discontinued
125 100
8

4

200

7

250

3DN
1DN
production of discontinued
150 150
12

5

300

4

300

3DN
1DN
production of discontinued
200 250
20

8

500

4

350

3DN
1DN
production of discontinued
250 500
45

20

1000

4

450

3DN
1DN
production of discontinued
300 600
50

25

1200

2

500

3DN
1DN
production of discontinued

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
3 623 visitors yesterday
visitors per month
23 501 from United States
73 417 from all countries
add your company to the catalog