PolluStat EX Sensus
Heat meter

production of discontinued

calculation and selection
93 % - model rating
Drawing PolluStat EX Sensus Heat meter
Паспорт
Сертифікат відповідності
Сертифікат затвердження
Model
PolluStat EX
Manufacturer
Country
Slovakia
Сalculator
PolluStat EX
Accuracy class according to EN 1434-1
2
Construction
single-piece construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
16 months
Daily archive
not provided
Archive by hours
not provided
Downtime
registers
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
150 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
100 mm
Tmax
180 °C
Tmin
2.0 °C
Standard cable length
2.0 m
Maximum cable length
23 m
Flow sensor
PolluStat EX
Type
ultrasonic
Dynamic range
1:100
Standard cable length
1,5 | 3,0 m
Maximum cable length
3.0 m
PN
25 / 16
Tmax
150 °C
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
20 G1 0.60
0.60
1.5
1.5
-

-

-

-

0.006

0.006

0.015

0.015

1.2

1.2

3.0

3.0

20

20

20

20

110

190

110

190

not required
not required
production of discontinued



20 G2 2.5
2.5
-

-

0.025

0.025

5.0

5.0

20

20

130

190

not required
not required
production of discontinued

20 FL 0.60
1.5
2.5
-

-

-

0.006

0.015

0.025

1.2

3.0

5.0

20

20

20

190

190

190

3DN
1DN
production of discontinued


25 G 3.5
6.0
-

-

0.035

0.060

7.0

12

6.0

9.0

260

190

not required
not required
production of discontinued

25 FL 3.5
6.0
-

-

0.035

0.060

7.0

12

6.0

9.0

260

190

3DN
1DN
production of discontinued

40 G 10
-

0.10

20

4.0

300

not required
not required
production of discontinued
40 FL 10
-

0.10

20

4.0

300

3DN
1DN
production of discontinued
50 FL 15
-

0.15

20

10

270

3DN
1DN
production of discontinued
65 FL 25
-

0.25

50

7.0

300

3DN
1DN
production of discontinued
80 FL 40
-

0.40

80

1.0

300

3DN
1DN
production of discontinued
100 FL 60
-

0.60

120

1.0

360

3DN
1DN
production of discontinued

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
3 623 visitors yesterday
visitors per month
23 501 from United States
73 417 from all countries
add your company to the catalog