Model
Sharky VMT
Manufacturer
Country
Germany
Сalculator
Energy INT 6
Accuracy class according to EN 1434-1
4
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
24 months
Daily archive
Archive by hours
Downtime
registers
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
147 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
34 | 84 mm
Tmax
150 °C
Tmin
5.0 °C
Standard cable length
? m
Maximum cable length
? m
Flow sensor
Sharky FS 473
Type
ultrasonic
Dynamic range
?
Standard cable length
? m
Maximum cable length
? m
PN
16 | 25 | 40
Tmax
130 | 150
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 0.60
1.5
-

-

0.006

0.015

1.2

3.0

9.0

8.0

110

110

not required
not required
production of discontinued

20 0.60
1.5
2.5
2.5
-

-

-

-

0.006

0.006

0.010

0.019

1.2

3.0

5.0

5.0

9.0

8.0

10

10

130

130

130

190

not required
not required
production of discontinued



25 3.5
6.0
-

-

0.035

0.024

7.0

12

4.0

13

260

260

not required
not required
production of discontinued

32 3.5
6.0
-

-

0.035

0.024

7.0

12

4.0

13

260

260

not required
not required
production of discontinued

40 10
10
-

-

0.040

0.10

20

20

10

10

300

300

not required
not required
production of discontinued

50 15
15
-

-

0.060

0.15

30

30

8.0

8.0

270

270

not required
not required
production of discontinued

65 25
25
-

-

0.10

0.25

50

50

8.0

8.0

300

300

not required
not required
production of discontinued

80 40
-

0.16

80

8.0

300

not required
not required
production of discontinued
100 60
60
-

-

0.24

0.60

120

120

8.0

8.0

360

360

not required
not required
production of discontinued

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
4 090 visitors yesterday
visitors per month
28 256 from United States
74 238 from all countries
add your company to the catalog