Warning: file_get_contents(http://ip-api.com/json/3.138.114.195?fields=country,currency): failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests in /home/teren/public_html/blocks/folder.php on line 28
Ultraheat T450 Landis Gyr - Heat meter

buy a Ultraheat T450 Landis Gyr in Land of dreams

No supplier Landis Gyr from Land of dreams is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Ultraheat T450
Manufacturer
Country
Germany
Сalculator
Ultraheat T450
Accuracy class according to EN 1434-1
2
Construction
single-piece construction
Power supply
from power element (battery)
Yearly archive
20 years
Monthly archive
60 months
Daily archive
400 days
Archive by hours
1472 hours
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
120 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
45 / 100 mm
Tmax
150 °C
Tmin
0 °C
Standard cable length
1.5 m
Maximum cable length
10 m
Flow sensor
Ultraheat T450
Type
ultrasonic
Dynamic range
1:100
Standard cable length
1.5 m
Maximum cable length
5.0 m
PN
25 / 16
Tmax
130 °C
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 0.60
1.5
-

-

0.006

0.015

1.2

3.0

15

17

110

110

not required
not required
add your price

20 0.60
1.5
1.5
2.5
2.5
-

-

-

-

-

0.006

0.015

0.015

0.025

0.025

1.2

3.0

3.0

5.0

5.0

15

16

16

18

21

190

130

190

130

190

not required
not required
add your price




25 3.5
6.0
-

-

0.035

0.060

7.0

12

16

23

260

260

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in Land of dreams. Join the community and you will receive emails with requests for work in Land of dreams from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
2 659 visitors yesterday
visitors per month
46 from Land of dreams
74 238 from all countries
add your company to the catalog