buy a Multical 603 Kamstrup in United States

No supplier Kamstrup from United States is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Multical 603
Manufacturer
Country
Denmark
Сalculator
Multical 601
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
20 years
Monthly archive
36 months
Daily archive
460 days
Archive by hours
1400 hours
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
178 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt100/Pt500
Length of the sensor
27,5 / 47 mm
Tmax
180 °C
Tmin
2.0 °C
Standard cable length
1.5 m
Maximum cable length
100 m
Flow sensor
ULTRAFLOW 54
Type
ultrasonic
Dynamic range
1:100
Standard cable length
2,5 / 5,0 m
Maximum cable length
100 m
PN
25 / 16
Tmax
130 °C
Tmin
2.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 G 0.60
1.5
1.5
-

-

-

0.006

0.015

0.015

1.2

3.0

3.0

4.0

22

22

110

110

165

not required
not required
add your price


20 G 0.60
1.5
1.5
2.5
-

-

-

-

0.006

0.015

0.015

0.025

1.2

3.0

3.0

5.0

4.0

0.22

0.22

3.0

130

130

190

190

not required
not required
add your price



20 FL 1.5
2.5
-

-

0.015

0.025

3.0

5.0

0.22

3.0

190

190

not required
not required
add your price

25 G 3.5
6.0
-

-

0.035

0.060

7.0

12

7.0

20

260

260

not required
not required
add your price

25 FL 3.5
6.0
-

-

0.035

0.060

7.0

12

7.0

20

260

260

not required
not required
add your price

40 G 10
-

0.10

20

6.0

300

not required
not required
add your price
40 FL 10
-

0.10

20

6.0

300

not required
not required
add your price
50 FL 15
-

0.15

30

14

270

not required
not required
add your price
65 FL 25
-

0.25

50

6.0

300

not required
not required
add your price
80 FL 40
-

0.40

80

5.0

300

not required
not required
add your price
100 FL 60
100
-

-

0.60

1.0

120

200

3.0

7.0

360

360

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
3 623 visitors yesterday
visitors per month
23 501 from United States
73 417 from all countries
add your company to the catalog