Pollutherm F Sensus
Heat meter

calculation and selection
91 % - model rating
Drawing Pollutherm F Sensus Heat meter Scheme Pollutherm F Sensus Heat meter
PolluFlow Data sheet
PolluTherm F Data sheet
Resistance thermometer Data sheet

buy a Pollutherm F Sensus in United States

No supplier Sensus from United States is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Pollutherm F
Manufacturer
Country
Slovakia
Сalculator
Pollutherm F
Accuracy class according to EN 1434-1
2.0
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
15 months
Daily archive
not provided
Archive by hours
not provided
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
100 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
93 / 148 mm
Tmax
150 °C
Tmin
0 °C
Standard cable length
1.5 m
Maximum cable length
10 m
Flow sensor
Polluflow
Type
ultrasonic
Dynamic range
1:100
Standard cable length
2.5 m
Maximum cable length
2.5 m
PN
25 / 16
Tmax
130 / 90
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 G 0.60
1.5
-

-

0.006

0.015

1.2

3.0

10

12

110

110

not required
not required
add your price

20 G 0.60
1.5
2.5
2.5
-

-

-

-

0.006

0.015

0.025

0.025

1.2

3.0

5.0

5.0

9.0

8.0

10

10

130

130

130

190

not required
not required
add your price



20 F 0.60
1.5
2.5
-

-

-

0.006

0.015

0.025

1.2

3.0

5.0

190

190

190

not required
not required
add your price


25 G 3.5
3.5
6.0
6.0
-

-

-

-

0.035

0.035

0.060

0.060

7.0

7.0

12

12

5.0

6.0

13

13

150

260

150

260

not required
not required
add your price



25 F 3.5
6.0
-

-

0.035

0.060

7.0

12

6.0

13

260

260

not required
not required
add your price

32 G 6.0
-

0.060

12

13

260

not required
not required
add your price
40 G 10
10
-

-

0.10

0.10

20

20

8.0

8.0

200

300

not required
not required
add your price

40 F 10
-

0.10

20

8.0

300

not required
not required
add your price
50 F 15
-

0.15

30

14

270

not required
not required
add your price
65 F 25
-

0.25

50

8.0

300

not required
not required
add your price
80 F 40
-

0.40

80

8.0

300

not required
not required
add your price
100 F 60
-

0.60

120

8.0

360

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
4 090 visitors yesterday