Zelsius C5-IUF Zenner
Heat meter

calculation and selection
95 % - model rating
Scheme Zelsius C5-IUF Zenner Heat meter
Data sheet
Manual
instruction for use

buy a Zelsius C5-IUF Zenner in United States

No supplier Zenner from United States is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Zelsius C5-IUF
Manufacturer
Country
Germany
Сalculator
Zelsius C5-IUF
Accuracy class according to EN 1434-1
2.0
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
24 months
Daily archive
not provided
Archive by hours
not provided
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
130 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt1000
Length of the sensor
45 / 27.5 mm
Tmax
150 °C
Tmin
0 °C
Standard cable length
1.5 m
Maximum cable length
5.0 m
Flow sensor
Zelsius C5-IUF
Type
ultrasonic
Dynamic range
1:100
Standard cable length
1.2 m
Maximum cable length
1.2 m
PN
25 / 16
Tmax
130 °C
Tmin
0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 G 0.60
1.5
-

-

0.006

0.015

1.2

3.0

25

25

110

110

not required
not required
add your price

20 G 0.60
1.5
2.5
2.5
-

-

-

-

0.006

0.015

0.025

0.025

1.2

3.0

5.0

5.0

25

25

25

25

190

190

190

130

not required
not required
add your price



20 F 0.60
1.5
2.5
-

-

-

0.006

0.015

0.025

1.2

3.0

5.0

25

25

25

190

190

190

not required
not required
add your price


25 G 3.5
3.5
6.0
6.0
-

-

-

-

0.035

0.035

0.060

0.060

7.0

7.0

12

12

25

25

25

25

150

260

150

260

not required
not required
add your price



25 F 3.5
6.0
-

-

0.035

0.060

7.0

12

25

25

260

260

not required
not required
add your price

32 G/F 6.0
-

0.060

12

25

260

not required
not required
add your price
40 G 10
10
-

-

0.10

0.10

20

20

25

25

200

300

not required
not required
add your price

40 F 10
-

0.10

20

25

300

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
3 623 visitors yesterday
visitors per month
23 501 from United States
73 417 from all countries
add your company to the catalog