Warning: file_get_contents(http://ip-api.com/json/3.147.7.14?fields=country,currency): failed to open stream: HTTP request failed! in /home/teren/public_html/blocks/folder.php on line 28
СВТУ 11Т М2 Семпал - Heat meter

СВТУ 11Т М2 Семпал
Heat meter

calculation and selection
101 % - model rating
Drawing СВТУ 11Т М2 Семпал Heat meter Design СВТУ 11Т М2 Семпал Heat meter Scheme СВТУ 11Т М2 Семпал Heat meter
Руководство по эксплуатации

buy a СВТУ 11Т М2 Семпал in Land of dreams

No supplier Семпал from Land of dreams is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
СВТУ 11Т М2
Manufacturer
Country
Ukraine
Сalculator
СВТУ-11Т
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
not provided
Daily archive
365 days
Archive by hours
1680 hours
Downtime
registers
Error registration
registers
Data retrieval
RS 232
Temperature difference Max
150 °C
Temperature difference Min
3 °C
Temperature sensor
ТС
Length of the sensor
58/80/150 mm
Tmax
150 °C
Tmin
0 °C
Standard cable length
2 m
Maximum cable length
20 m
Flow sensor
РУ
Type
ultrasonic
Dynamic range
1:100
Standard cable length
2 m
Maximum cable length
10 m
PN
16
Tmax
150 °C
Tmin
0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
20 5.0
0.12

0.05

6.5

40

270

not required
not required
add your price
32 22
0.60

0.22

30

15

180

not required
not required
add your price
50 70
1.40

0.70

90

27

180

see descr.
5DN
add your price
65 120
2.40

1.20

160

85

200

see descr.
5DN
add your price
80 180
3.60

1.80

230

85

210

see descr.
5DN
add your price
100 280
5.70

2.80

360

85

230

see descr.
5DN
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in Land of dreams. Join the community and you will receive emails with requests for work in Land of dreams from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
2 659 visitors yesterday
visitors per month
46 from Land of dreams
74 238 from all countries
add your company to the catalog