Warning: file_get_contents(http://ip-api.com/json/3.133.154.114?fields=country,currency): failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests in /home/teren/public_html/blocks/folder.php on line 19
Multical 303 Kamstrup - Compact heat meter

Please do not block ads on our site. Clicks on ads help us exist, grow and become more useful for you!

Multical 303 Kamstrup
Compact heat meter

calculation and selection
94 % - model rating
Drawing Multical 303 Kamstrup Compact heat meter Design Multical 303 Kamstrup Compact heat meter Scheme Multical 303 Kamstrup Compact heat meter
Calibration unit
Data sheet
Installation and user guide
Техническое описание

buy a Multical 303 Kamstrup in Land of dreams

No supplier Kamstrup from Land of dreams is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Multical 303
Manufacturer
Country
Denmark
Сalculator
Multical 303
Accuracy class according to EN 1434-1
2
Construction
single-piece construction
Power supply
from power element (battery)
Yearly archive
20 years
Monthly archive
36 months
Daily archive
460 days
Archive by hours
1400 hours
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
178 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
28 mm
Tmax
180 °C
Tmin
2.0 °C
Standard cable length
1.5 m
Maximum cable length
3.0 m
Flow sensor
Multical 303
Type
ultrasonic
Dynamic range
1:100
Standard cable length
1.5 m
Maximum cable length
1.5 m
PN
25 / 16
Tmax
130 °C
Tmin
2.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 0.60
1.5
-

-

0.006

0.015

1.2

3.0

3.0

9.0

110

110

not required
not required
add your price

20 1.5
2.5
-

-

0.015

0.025

3.0

5.0

9.0

9.0

130

130

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
water flow rate
through the heat meter
m³/h

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in Land of dreams. Join the community and you will receive emails with requests for work in Land of dreams from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
1 734 visitors yesterday
visitors per month
291 from Land of dreams
43 891 from all countries
add your company to the catalog