Warning: file_get_contents(http://ip-api.com/json/3.129.23.109?fields=country,currency): failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests in /home/teren/public_html/blocks/folder.php on line 28
Esquemas de instalación de las válvulas de bypass automático

Esquemas de instalación de las válvulas de bypass automático

Esquemas de instalación de las válvulas de bypass automático

A bypass valve is installed in the bypass line in the pump assembly for systems with highly variable flow rates. When the flow rate in the system, and therefore through the pump, decreases, the head generated by the pump increases, resulting in an increase in the differential pressure between the suction and discharge ports of the pump. The bypass valve responds to this increase and opens, allowing the heat transfer fluid to flow from the discharge port to the suction port, thereby maintaining a constant flow rate through the pump.



Boiler bypass valve

The bypass valve is installed in the jumper between the supply and return piping in the non-condensing boiler assembly. In this configuration, it is necessary for creating an optimal operating mode for boilers in heating systems with thermostatic radiator valves and heat flow regulators.

When the regulators close, the flow rate of the heat transfer fluid circulating in the system decreases, which increases the head generated by the pump and, consequently, the differential pressure between the supply and return piping in the boiler room. The bypass valve responds to the increase and, by opening, bypasses the hot heat transfer fluid from the supply piping to the return piping, thereby ensuring a stable flow rate through the boiler, independent of flow rate fluctuations in the system.

In addition, hot heat transfer fluid enters the boiler, which reduces the probability of condensation of exhaust gases on the heat exchange surface of the boiler.

The purpose of the bypass valve in each of the described configurations is to create an optimal operating mode, both for individual elements and for the heating system as a whole.

* Explicación de los símbolos gráficos condicionales en los diagramas

pregunta : comentario : opinión

dónde notificar sobre la respuesta. no se publica en ningún lugar

93

Kvs
Coeficiente de flujo
m³/h
Presión de ajuste
bar
añadir su equipo al catálogo

comunidad de expertos

Estamos formando una comunidad de expertos en diseño, instalación y servicio de sistemas de calefacción, agua caliente y suministro de agua en Land of dreams. Únete a la comunidad y recibirás emails con solicitudes de trabajo en Land of dreams de nuestros visitantes.

diseño
instalación
servicio
calefacción
suministro de agua
acondicionamiento
publicidad en el sitio web
3 190 visitors yesterday
visitors per month
6 from Land of dreams
49 243 from all countries