Schéma de raccordement du réservoir d'expansion

Schéma de raccordement du réservoir d'expansion

Schéma de raccordement du réservoir d

Connection scheme for the expansion tank to the heating system should include:

A shut-off valve - for disconnecting the tank from the system and checking the initial pressure in the gas cavity.

A drain valve - for draining water from the tank.

A pressure gauge to monitor the pressure at the point of connection of the expansion tank.

A safety valve - to protect the heating system from emergency pressure exceeding the maximum allowable value.


Connecting an expansion tank to the heating system

Expansion tanks for heating systems are used in buildings with autonomous sources of heat and in buildings connected to the heating network using an independent scheme.

The expansion tank is connected before the suction nozzle of the circulation pump, and there should be no elements that introduce significant hydraulic resistance between the connection point of the tank and the pump. This connection scheme ensures a stable excess pressure in the heating system, regardless of the thermal and hydraulic regimes.

The connection is made using detachable connections, as during operation, it may be necessary to disconnect the tank for repairs.

Another feature of membrane expansion tanks is the increase in pressure in the heating system with increasing water temperature. Therefore, the tank should be designed so that at maximum water temperature, the pressure does not exceed the maximum allowable value, and at minimum temperature, it does not become less than the pressure necessary to fill the heating system. To avoid pressure fluctuations in the heating system with temperature changes, an expansion tank can be installed, the pressure in the gas cavity of which is maintained by a compressor.

Expansion tank for a boiler

Expansion tank for a boiler is necessary only if the boiler is connected to a closed circuit that is not connected to the atmosphere. It protects the boiler and the connected heating or hot water supply system from pressure exceeding the maximum allowable value. Low-power boilers (up to 30 kW) are usually equipped with expansion tanks as standard, while for boilers with higher power, they need to be selected separately.

* Explication des symboles graphiques conditionnels dans les schémas

question : commentaire : retour

où notifier de la réponse. n'est publié nulle part

241

Volume du réservoir
litres
PN
Pression nominale PN
bar
ajoutez votre équipement au catalogue

communauté d'experts

Nous réunissons une communauté d'experts dans la conception, l'installation et l'entretien des systèmes de chauffage, d'eau chaude et d'approvisionnement en eau en Land of dreams. Rejoignez la communauté et vous recevrez des emails avec des demandes de travail en Land of dreams de la part de nos visiteurs.

conception
installation
entretien
chauffage
approvisionnement en eau
climatisation
publicité sur le site web
3 190 visitors yesterday
visitors per month
6 from Land of dreams
49 243 from all countries