Schéma d'installation d'un compteur de chaleur compact

Schéma d'installation d'un compteur de chaleur compact

Schéma d

Installation of a flat heat meter is carried out according to the classical scheme, in which the flowmeter is installed in the supply or return pipeline, and temperature sensors in the supply and return pipelines.

The installation location of the flowmeter (whether it is in the supply or return pipeline) is determined by the factory firmware of the meter. This is due to the fact that when calculating the amount of heat consumed, the meter calculates the mass flow rate (t/h) from the volumetric flow rate (m³/h) obtained from the flowmeter, taking into account the density of water from the temperature sensor installed on the same pipeline as the flow sensor. The factory firmware sets the signal for which sensor to use in the calculation.

Ball valves should be installed on both sides of the flowmeter section of the heat meter, which are necessary for disconnection during the device dismantling for the period of verification without draining the system. In addition, many apartment owners use the second ball valve in the direction of the heat carrier as a regulating device to limit the supply to the apartment.

To protect the flow sensor from solid abrasive particles present in the heat carrier flow, especially for mechanical heat meters, a mesh filter should be installed in front of the flowmeter.

Heat meters with ultrasonic flow meters are insensitive to water quality and can be installed on pipelines without additional protection with a mesh filter, unless otherwise specified by the project or installation instructions.

The installation location of the flat heat meter must be outside the apartment and accessible for checking readings by employees of the heat supply organization.

When installing flat heat meters, additional control-measuring devices (manometers and thermometers) are not installed.

* Explication des symboles graphiques conditionnels dans les schémas

question : commentaire : retour

où notifier de la réponse. n'est publié nulle part

82

Débit d'eau
m³/h
ajoutez votre équipement au catalogue

communauté d'experts

Nous réunissons une communauté d'experts dans la conception, l'installation et l'entretien des systèmes de chauffage, d'eau chaude et d'approvisionnement en eau en Land of dreams. Rejoignez la communauté et vous recevrez des emails avec des demandes de travail en Land of dreams de la part de nos visiteurs.

conception
installation
entretien
chauffage
approvisionnement en eau
climatisation
publicité sur le site web
3 190 visitors yesterday
visitors per month
6 from Land of dreams
49 243 from all countries