Specifiche tecniche della valvola a sferaSpecifiche tecniche della valvola a sfera

Specifiche tecniche della valvola a sferaSpecifiche tecniche della valvola a sfera

Class of tightness - determines the maximum allowable leakage through the closed ball valve at atmospheric pressure on one side and water pressure of 1.1*PN on the other side. The water temperature during testing should be in the range of 5 to 40°C.

  • Class A - no leakage
  • Class B - no more than 0.0006*DN(mm) cm³/min
  • Class C - no more than 0.0018*DN(mm) cm³/min
  • Class D - no more than 0.006*DN(mm) cm³/min

Most ball valves have a class of tightness A.

DN - nominal diameter - is used to indicate the sizes of pipeline fittings, has no dimension, and the numerical value of DN is approximately equal to the internal diameter of the connected pipeline in millimeters. Nominal diameter is applicable to all pipeline elements except pipes and components characterized by an external diameter.

PN - nominal pressure - is the maximum excess pressure of the working medium at a temperature of 20°C, at which prolonged operation of the ball valve is permissible.

Testing pressure - is the excess pressure that must be used for hydraulic strength and tightness testing with water at temperatures from 5 to 70°C, if a different test temperature is not specified in the passport of the ball valve or normative documentation.

Dependence of working pressure on temperature

Working pressure - is the maximum excess pressure at which the specified operating mode of the shut-off valve is ensured, taking into account the temperature of the working medium. The value of the working pressure is usually less than the value of the nominal pressure, so the mode of operation simultaneously with the maximum operating temperature and nominal pressure is not allowed.

Kvs - flow coefficient - is numerically equal to the flow rate of water in m³/h at a temperature of 20°C, at which the pressure drop on the valve is 1 bar. The value of the flow coefficient is used in hydraulic calculations to determine the pressure drop on elements of pipeline systems.

domanda : commento : feedback

dove notificare sulla risposta. non pubblicato da nessuna parte

80

DN
Diametro nominale DN
mm
PN
Pressione nominale PN
bar
aggiungi il tuo prodotto al catalogo

comunità di esperti

Stiamo riunendo una comunità di esperti nella progettazione, installazione e manutenzione di sistemi di riscaldamento, acqua calda e fornitura di acqua in Land of dreams. Unisciti alla comunità e riceverai email con richieste di lavoro in Land of dreams dai nostri visitatori.

progettazione
installazione
manutenzione
riscaldamento
fornitura d'acqua
condizionamento
pubblicità sul sito web
3 190 visitors yesterday
visitors per month
6 from Land of dreams
49 243 from all countries