Warning: file_get_contents(http://ip-api.com/json/3.144.92.83?fields=country,currency): failed to open stream: HTTP request failed! in /home/teren/public_html/blocks/folder.php on line 28
Ajuste da pressão no vaso de expansão

Ajuste da pressão no vaso de expansão

Ajuste da pressão no vaso de expansão

Before connecting the expansion vessel to the water supply system, the initial pressure of the gas space must be created.

In an empty expansion vessel with a previously created pressure of the gas space , the entire volume of the tank is filled with air (nitrogen gas).

After the pump is turned on, the system is filled with water and as soon as the water pressure exceeds the initial pressure of the gas space, the water, stretching the membrane and compressing the gas, enters the expansion vessel, and when the minimum working pressure Pmin for the water supply system is reached, it fills it by 10-15%.

A 15% water reserve in the expansion vessel tank is necessary to cover the water consumption during the time from the moment the pump is turned on until the water arrives from the pump to the water distribution valve. In the absence of a reserve, an unstable water consumption mode with interruptions is possible at the moment when all the water has been squeezed out of the expansion vessel, but the pump has not yet turned on.

How to create pressure in an expansion vessel tank

The initial pressure of the gas space is calculated for specific operating conditions. You can calculate the pressure in the expansion vessel in the [Calculations] section on our website. If the initial pressure of the gas space of the expansion vessel, set at the factory, exceeds the calculated value, it should be lowered by releasing the air, and if it is less, the pressure should be raised using a compressor.

The initial pressure of the gas space is accepted at 0.2 - 1 bar less than the pump turn-on pressure. The further the expansion vessel tank is installed from the point of maintaining constant pressure, the less gas pressure should be accepted initially.

The [Calculations] section provides a program that will help you determine all the parameters necessary for setting the pressure in the expansion vessel: the initial pressure of the gas space , the turn-on pressure Pmin, and the turn-off pressure Pmax of the pump, for specific conditions.

pergunta : comentário : opinião

onde notificar sobre a resposta. não publicado em nenhum lugar

111

Volume do tanque
litros
PN
Pressão nominal PN
bar
adicionar o seu produto ao catálogo

comunidade de especialistas

Estamos reunindo uma comunidade de especialistas em design, instalação e manutenção de sistemas de aquecimento, água quente e abastecimento de água em Land of dreams. Junte-se à comunidade e você receberá emails com pedidos de trabalho em Land of dreams dos nossos visitantes.

projeto
instalação
manutenção
aquecimento
abastecimento de água
ar condicionado
publicidade no site
3 190 visitors yesterday
visitors per month
6 from Land of dreams
49 243 from all countries